Eradicating Slimelung From Polluted Oxygen: A Comprehensive Guide

how to remove slimelung from polluted oxygen

Slimelung is a type of germ commonly found in slime and polluted oxygen. It is generally abundant in the Swamp Biome, and can be contracted by dupes through inhaled air or surface contact. While it is not lethal, slimelung can slow dupes down by impeding their productivity and causing a -3 penalty in athletics and coughing. To remove slimelung from polluted oxygen, deodorizers can be used to purify the polluted oxygen into oxygen, reducing the germ count. Another method is to use radiation lamps or Wheezewort to create radiation, which kills slimelung over time. Additionally, placing slimelung-infested tiles in regular oxygen (not polluted oxygen) is an easy but slow method to kill off the germs.

How to remove slimelung from polluted oxygen

Characteristics Values
Prevention Avoid digging out slimelung-infested slime tiles as this spreads the germs
Store slime underwater or in a pool of chlorine to kill the germs
Use multiple ore scrubbers to clean tiles
Monitor dupes to ensure they do not carry slimelung-infested tiles past the ore scrubbers
Ensure Swamp Biomes are cold to prevent slimelung
Treatment Use deodorizers to purify polluted oxygen into oxygen and reduce the germ count
Use a Radiation Lamp and Wheezewort to create radiation, which kills slimelung over time
Use germy debris in chlorine to kill the germs
Use a Medical Pack crafted at an Apothecary, administered by a duplicant with the Bedside Manner skill in a Sick Bay

shunwaste

Use deodorizers to purify polluted oxygen

Deodorizers are an effective way to purify polluted oxygen and reduce the number of slimelung germs. They do not directly remove the germs, but they clean the air, which helps to kill the slimelung over time. This method is simple and requires little power and few resources to set up. It is recommended to place deodorizers wherever you see polluted oxygen.

To understand why deodorizers are effective, it is important to know how slimelung spreads. Slimelung is a type of germ commonly found in the Swamp Biome. It is abundant in slime and quickly multiplies in polluted oxygen, infecting surrounding solid tiles and nearby gases once the slime tiles are dug out. While consuming items with slimelung has no effect, inhalation and surface contact with heavily contaminated materials can infect duplicants. Infected duplicants will experience symptoms such as coughing and a slower rate of air loss, making them less suited for working in low-oxygen environments.

To prevent the spread of slimelung, it is crucial to address the source of the problem. Simply digging out the slime will not solve the issue, as the exposed slime will continue to be a source of infection. Instead, it is recommended to build a storage bin underwater or, even better, store the slime in a pool of chlorine, which will slowly kill the germs.

In addition to deodorizers, there are other methods to kill slimelung. Radiation lamps and Wheezewort can be used to create radiation, which is effective in killing the germs. Natural slime tiles need to be exposed to at least 16-20 rads/cycle, and higher levels of radiation may be required for objects with more germs. Other sources of radiation, such as cosmic radiation, crashed satellites, or Shine Bugs, can also be utilised.

By combining the use of deodorizers with proper storage of slime and, if needed, creating radiation, you can effectively purify polluted oxygen and reduce the presence of slimelung germs in your environment.

shunwaste

Store slime in a pool of chlorine

Storing slime in a pool of chlorine is an effective way to prevent the spread of slimelung. Slime begins to spread when a slimelung-infested slime tile is dug out, as the slime starts to off-gas polluted oxygen contaminated with slimelung germs. By storing the slime in a pool of chlorine, you can kill these germs and prevent them from spreading further.

To effectively use this method, there are a few considerations to keep in mind. Firstly, slime will only stop emitting polluted oxygen when the pressure is above 1800g/tile, so maintaining this pressure level in your chlorine room is crucial to success. Additionally, as chlorine is lighter than carbon dioxide, any exhaled carbon dioxide by dupes in the chlorine pit will cause the chlorine level to rise, which might affect your design.

Another challenge is determining how long the slime needs to remain in the chlorine room. The duration depends on the amount of germs present on the slime, and you don't have control over which slime is picked up by Duplicants or auto sweepers. This means that they could pick up slime that has not been adequately sanitized.

To address this issue, you can utilize a transporting system with rails that run through the chlorine room. By doing so, you can ensure that the slime travels a sufficient distance and duration to be effectively sanitized before it is picked up. Additionally, you can separate the chlorine chamber from the outside by walling it off completely or using a liquid lock if Duplicants need to pass through.

By following these steps and considerations, you can effectively use a pool of chlorine to store slime and prevent the spread of slimelung.

shunwaste

Use a radiation lamp and Wheezewort to create radiation, killing Slimelung

Slimelung is a type of germ commonly found in polluted oxygen that can be harmful to dupes. While it is not lethal, it can impede their productivity. To remove slimelung from polluted oxygen, one effective method is to use a radiation lamp and Wheezewort to create radiation, which will kill the germs over time.

Wheezewort is a non-reproducing plant that is found in the Frozen Biome. It has porous outer membranes that allow it to absorb heat and respire. Wheezeworts can be planted in planter boxes, farm tiles, or hydroponic farms and require a temperature range of -60°C to 95°C. They are excellent for temperature management as they can destroy heat from the surrounding environment. The radiation emitted by Wheezeworts can be captured using Radbolt Generators, which are most effective when placed close to the Wheezewort.

Radiation lamps, on the other hand, emit radiation that can kill slimelung germs. To achieve a net decrease in germ count, expose natural slime tiles to at least 16-20 rads/cycle, and increase the radiation for objects with higher germ counts. This combination of Wheezewort and radiation lamps creates a sterile environment that will kill the slimelung germs over time.

It is important to note that slimelung can also be removed by other methods. For instance, placing slimelung-infested tiles in regular oxygen will eventually kill the germs, although this is not the fastest method. Additionally, deodorizers can be used to purify polluted oxygen, although they do not directly remove the germs. Instead, the clean air they produce will kill the slimelung over time.

In conclusion, by using a combination of radiation lamps and Wheezewort, you can effectively create radiation that will kill slimelung germs in polluted oxygen. This method, along with proper management of infected tiles and the use of deodorizers, can help maintain a sterile environment for your dupes to operate efficiently.

shunwaste

Use multiple ore scrubbers to kill germs

Slimelung is a type of germ commonly found in slime and polluted oxygen. It can be contracted by dupes through inhalation and surface contact with contaminated materials, causing them to become ill and slowing them down. While slimelung is not lethal, it can multiply quickly in polluted oxygen and infect large areas.

To remove slimelung from polluted oxygen, one effective method is to use multiple ore scrubbers. Ore scrubbers can help remove slimelung germs, but a single scrubber may not be sufficient for heavily contaminated areas. By setting up several ore scrubbers in a row, you can increase their effectiveness and ensure that all the germs are killed. However, this method can be labour-intensive as it requires constant monitoring to ensure that dupes do not carry infested tiles past the scrubbers.

It is important to note that slimelung does not spread between natural tiles. However, it can spread from natural tiles to constructed tiles and the surrounding gases once the slime tiles are dug out. Therefore, it is crucial to use ore scrubbers proactively to prevent the spread of slimelung to other areas of your base.

Additionally, you can combine the use of ore scrubbers with other methods to further combat slimelung. For example, deodorizers can be placed near infected areas to purify polluted oxygen into oxygen, reducing the germ count. Storing slime tiles underwater or in a pool of chlorine can also help kill off the germs over time.

By employing multiple strategies, including the use of multiple ore scrubbers, you can effectively manage and eliminate slimelung from polluted oxygen, ensuring the health and productivity of your dupes.

shunwaste

Cure Slimelung with a medical pack

Slimelung is a common issue in the slime biome, where it can be found in polluted oxygen. While slimelung is more of a nuisance than a threat, it can slow your dupes down. A dupe that becomes infected gets a Slimelung debuff that lasts for 3 cycles, causing a -3 penalty in athletics and coughing.

To cure slimelung, you need a dupe with the Bedside Manner skill, which requires two points in the Doctoring skill tree. This dupe can then use a medical pack to cure the infected dupe instantly. To manufacture a medical pack, you will need balm lily flower and phosphorite. The balm lily flower grows in chlorine, in the same biome as dreckos. Phosphorite can be dug up on the map and is also produced by dreckos.

If you want to prevent the spread of slimelung, you can submerge slimelung-infested slime in liquid so it can't off-gas polluted oxygen. You can do this by having storage bins submerged in liquid or using an automatic dispenser that dumps debris into the liquid. Another option is to use an ore scrubber, which will remove germs from slimelung-infested tiles. However, this method can be labour-intensive as you will need to have several ore scrubbers in a row and keep an eye on all dupes to ensure they put germy tiles in the ore scrubber.

In addition to using medical packs to cure infected dupes, you can also use curative tablets to treat food poisoning and vitamin chews or immuno boosters to reduce the chance that dupes will contract slimelung.

Frequently asked questions

Deodorizers can be placed near polluted oxygen to purify it into oxygen and reduce the germ count.

Slimelung can be treated with a Medical Pack crafted at an Apothecary and administered by a duplicant with the Bedside Manner skill in a Sick Bay. Other sources of radiation that might be effective at dealing with Slimelung include Cosmic Radiation, Crashed Satellites, or Shine Bugs.

Slimelung spreads from natural tiles to constructed tiles. To prevent its spread, you can use ore scrubbers to kill off germs. Alternatively, you can store slime underwater or in a pool of chlorine, which will slowly kill off germs.

An infected duplicant will experience a -3 penalty in athletics and coughing. They will also lose air at a faster rate than they can passively regain it, forcing them to cough occasionally. This can interrupt jobs or sleep and spread the infection to other duplicants.

Written by
Reviewed by

Explore related products

Share this post
Print
Did this article help you?

Leave a comment